NFORMATION
Before carrying out any installation or removal of
components, or any maintenance procedures on
the Switch, you must read the following safety
information.
Important Safety Information
WARNING: Warnings contain directions that you
must follow for your personal safety. Follow all
instructions carefully.
Please read the following safety information thor-
oughly before installing the Switch.
■
Installation and removal of the unit must be car-
ried out by qualified personnel only.
■
If installing the Switch unit in a stack with Super-
Stack II Hub units, the Switch unit must be
installed below the narrower Hub units.
■
This unit must be earthed.
■
Connect the unit to an earthed power supply to
ensure compliance with European safety stan-
dards.
■
The power cord set must be approved for the
country where it will be used.
■
The appliance coupler, that is, the connector to
the device itself and not the wall plug, must have
a configuration for mating with an
EN60320/IEC320 appliance inlet.
■
For U.S.A. and Canada:
■
The cord set must be UL-approved and CSA
certified.
■
The minimum specification for the flexible cord
are:
No. 18 AWG
Type SV or SJ
3-conductor
■
The cord set must have a rated current capac-
ity of at least 10A.
■
The attachment plug must be an
earth-grounding type with a NEMA 5-15P
(15A, 125V) or NEMA 6-15P (15A, 250V) con-
figuration.
■
For Denmark:
■
The supply plug must comply with section
107-2-D1, standard sheet DK2-1a or DK2-5a.
■
For Switzerland:
■
The supply plug must comply with SEV/ASE
1011.