DpuScan Scamax 2600 / 5000 Scanner Options
Fixed Text
In addition to numeric values such as counters or flags, the endorser can
print text.
Only the printout text is limited to the number of characters selected here.
The text itself has to be entered in the field "Fixed Text Field", as seen
below. It can hold up to 15 characters.
It makes sense to enter a long, fixed text a lot of information and
send it along with the header to the scan application. On the other
hand, it may be applicable to print out only a small part of the text on
the original document to keep as close to its "original" state as
possible.
Delimiter
You can choose a delimiter to separate Sequential ID, level, mode, and
flags. This character will be printed after a parameter, on the condition
that in at least one of the boxes "Don't print" is not selected.
5.3.5 Preview of Endorser and Header
At the bottom of the Parameter Configuration dialog is a frame titled Endorsement Preview. It
contains an input field for the fixed endorser text, a grayed field for the summary of all counters and
flags output, and some lines that show how many characters are left for the several output fields.
Fixed Text Field
In addition to numeric values such as counters or flags, the endorser can
print text. The text is limited to 15 characters.
The first 10 characters from this string comprise the first (leftmost) part of
Image Address.
Numeric Fields
This field gives an idea of the printout; numbers with leading zeros are
shown as a sequence of zeros ("000"). Numbers with a fixed length are
shown as number/pound signs ("###").
The flags are displayed as their character, where ”L" means latched and
"M" stands for momentary.
If a number has variable length or a flag may be omitted (if unset), the
placeholder is a question mark ("?").
For a SCAMAX the Counter A and the rightmost delimiter are
handled differently by the driver than the other counters, flags, and
delimiters. They do not account for the calculation of the maximum
field length.
The overall length for endorser text is limited by several machine
dependent parameters. For example, with a SCAMAX scanner, the fixed
text field and numeric fields are limited to 15 characters each (except
Counter A and its delimiter, as seen above).
Page 30 of 42