ADC Campus-REX RS Interface Card Network Card User Manual


 
Set Up the Campus-REX System
Campus-REX RS Interface Card User Manual 3-29
SET THE TIMING SOURCE
The Timing Source option determines the source of circuit timing on the
HDSL link. There are two settings for the Timing Source option:
Internal: Sets the Campus unit to take its timing from an internal
oscillator. This is the default setting.
HDSL: Sets the Campus unit to take its timing from the HDSL link.
The proper setting of the Timing Source option depends upon the interface
card of the remote Campus unit:
If the Campus-REX is connected to a Campus unit with another
Campus-REX RS Interface Card, leave the Timing Source option set to
Internal. The Campus system will not operate properly if both units are
set to HDSL.
If the Campus-REX is connected to a Campus unit with a synchronous
interface card, such as a Fractional V.35 card, the timing source depends
on the setting of the Primary Timing Source option of the remote unit:
Set the Timing Source to HDSL if the remote unit is set to Internal
or Port.
Set the Timing Source to Internal if the remote unit is set to HDSL.
See the Campus-RS Fractional Interface Card User Manual for
information on the Primary Timing Source option.
If the Campus-REX is connected to a Campus unit with a Campus
CSU/DS-1 or CSU/DSX-1 interface card, leave the Timing Source
option set to Internal.