ADC Campus-REX RS Interface Card Network Card User Manual


 
Configuring and Monitoring through the LCD
Campus-REX RS Interface Card User Manual 4-7
Viewing 24-Hour HDSL Alarm History
You can view the number of HDSL alarm conditions that have occurred over
the past 24 hours. The LCD displays 24-hour information for the following
alarms:
local errored seconds (LOCAL ES)
remote errored seconds (REMOTE ES)
local unavailable seconds (LOCAL UAS)
remote unavailable seconds (REMOTE UAS)
You may also view the time when the counter was last cleared and clear the
counter.
To view the HDSL alarm history:
1 Press Escape until CAMPUS RS I/F: REX displays.
2 Press Next. HDSL LINK CONFIG & STATUS displays.
3 Press Enter, then press Next until PERFORMANCE STATUS displays.
4 Press Enter, then press Next to scroll through the alarm history displays.
5 To reset the counter, press Next until Press ENTER to clear
error cnts displays, then press Enter.
AutoSync Alarms
The system generates an AutoSync alarm if the HDSL Operating Mode is set
to AutoSync and an HDSL connection cannot be established in AutoSync
Mode. This alarm is generated even if the HDSL link is eventually established
through Fallback Mode. This section describes how to view and configure
this alarm.
CAD1069i5.book Page 7 Thursday, May 30, 2002 7:32 AM