ADC H2TU-C-388 Network Card User Manual


 
152-388-100-02, Issue 2 Front Panel
H2TU-C-388 List 1 June 6, 2000 5
Table 2 lists the front-panel display messages. The four-character display reports the code of an alarm, loopback,
or diagnostic message and, in some cases, is followed by a second four-character message that modifies the first
message with a value or current configuration setting.
Table 2. Front-Panel Display Messages
Message Full Name Description
SYSTEM ALARM MESSAGES
ACO Alarm Cutoff A system alarm has occurred and has been retired to an ACO condition
by pressing the SEL button on the H2TU-C front panel.
ALRM Alarm Condition Exists A system alarm condition is in effect.
DBER DS1 Bit Error Rate A system DS1 BER alarm is in effect and remains in effect until cleared.
HBER HDSL2 Block Error Rate A system HDSL2 Block Error Rate alarm is in effect.
LA Loop Attenuation Indicates that the attenuation on the HDSL2 loop has exceeded the
maximum threshold value.
LAIS Local Alarm Indication Signal Indicates an AIS (all ones) pattern is being transmitted from the local
DS1 output port.
LLOS Local Loss of Signal Indicates that no signal is detected at the DSX-1 input to the H2TU-C.
Causes a system alarm.
LOSW Loss of Sync Word Indicates that the HDSL2 loop has lost synchronization.
LRAI Line RAI Indicates an RAI alarm (yellow) from the CPE with an error-free signal
from the line unit or network.
MAL Margin Alarm The margin on HDSL2 loop has dropped below the threshold (0 to 15
dB) as set by the operator.
PWR FEED GND Ground The HDSL2 loop is grounded.
PWR FEED OPEN Open Indicates a line power open condition.
PWR FEED SHRT Short Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF Performance Report Messaging -
Far End
H2TU-R PRM-FE BER threshold has been exceeded.
PRMN Performance Report Messaging -
Near End
H2TU-R PRM-NE BER threshold has been exceeded.
RAIS Remote Alarm Indication Signal Indicates an AIS (all ones) pattern is being transmitted from the remote
DS1 output port.
RLOS Remote Loss of Signal Indicates that no signal is detected at the DS1 input to the H2TU-R.
Causes a system alarm.
RRAI Remote RAI Indicates an RAI alarm (yellow) from the CPE with errors from the line
unit or network.
TUC Transmission Unit Central Office Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-C central office unit.
TUR Transmission Unit Remote End Accompanies the HBER, MAL, and LA alarm and indicates that the alarm
has occurred at the H2TU-R remote unit.
LOOPBACK MESSAGES
CLOC Customer Local Loopback Signal from customer is looped back to the customer at the H2TU-R.
COLB Central Office Loopback Dual loopback at the H2TU-C.
CREM Customer Remote Loopback Signal from customer is looped back to the customer at the H2TU-C.
NLOC Network Local Loopback DSX-1 signal is looped back to the network at the H2TU-C.
NREM Network Remote Loopback DSX-1 signal is looped back to the network at the H2TU-R.
RULB Remote Unit Loopback Dual loopback at the H2TU-R.
Continued