ADC EMU-830 Network Card User Manual


 
Chapter 3: Provisioning September 25, 2006
3-10 LTPE-UM-3159-02
Configure SNMP Operation Over SLIP
To configure the EMU-830 for basic SNMP operation over SLIP:
Configure EMU Autoconfiguration through BOOTP
To use BOOTP capability of the EMU-830 (see Table 3-5):
Table 3-5. Network Parameters
Step Action
1 In the Network Parameters menu (Figure 3-5 on page 3-9), enter the Local SLIP IP Address (see Table
3-5 on page 3-10).
2 Enter the Local SLIP Subnet Mask.
3Use the SPACEBAR to select the SLIP Port Baud Rate.
4 Press ENTER to confirm all network settings.
5 Follow the EMU console prompt to reset the EMU.
Step Action
1 In the Network Parameters menu, enter the BOOTP Server IP Address.
2 Enter the BOOTP Gateway IP Address.
3 Toggle the Boot Mode from NVRAM to Network.
4 Press ENTER to confirm all network settings.
5 Follow the EMU console prompt to reset the EMU.
Option Function
Ethernet Address Reflects the hardware Ethernet (MAC) address for
the EMU-830. This field cannot be changed.
Ethernet Connection The Ethernet connection type is 10BASE-T. This
field cannot be changed.
Local IP Address Must be configured for the EMU-830 Ethernet port to
respond to the local management station.
192.168.0.1 is the default setting using Telnet or
SNMP.
Local IP Subnet Mask Allows the EMU-830 to determine if a host (TFTP
server, SNMP management station, or trap receiver)
is on the same local subnet. If it is, the EMU-830 can
communicate directly with the host; if it is not,
messages must be sent through a default router.
255.255.255.0 is the default setting
Default Gateway IP
Address
Enter the IP address of the default gateway the
EMU-830 will use if the EMU-830 and the host are
not on the same network. 0.0.0.0 is the default
setting.
Local SLIP IP Address Must be configured for the EMU-830 SLIP port to
respond to the local management station. 0.0.0.0 is
the default setting, which means SLIP port is not
used.