ADTRAN 1240 Network Router User Manual


 
Total Access 1240 Installation and Maintenance Practice
4-4 61179605L5-5B
G.991.2 Annex A
B
A/B
B
Lineprobing (PMMS) Disabled
Enabled - Current Condition
Enabled - Worst Case Condition
Disabled
PMMS Margin N/A
CC = N from 0 to 20, in dB
WC = N from –10 to 20, in dB
N/A
Loopback Timeout Disabled
1–999 minutes
Disabled
SNR Margin Alarm Threshold Disabled
1–15 minutes
Disabled
Loop Attenuation Alarm
Threshold
Disabled
1–127 dB
Disabled
ES 15 Minute Alarm Threshold Disabled
1–900 seconds
Disabled
SES 15 Minute Alarm
Threshold
Disabled
1–900 seconds
Disabled
UAS 15 Minute Alarm
Threshold
Disabled
1–900 seconds
Disabled
LOSWS 15 Minute Alarm
Threshold
Disabled
1–900 seconds
Disabled
CVC 15 Minute Alarm
Threshold
Disabled
1–65535 errors
Disabled
Table 4-4. User Port Default Provisioning Options (Continued)
Provisioning Option Available Options Default Setting