Chapter 4. Status
61200659L1-1 MX2800 STS-1 User Manual 4-7
Protection
This field lists the type of protection mode currently active.
Possible states are listed in the following chart:
Card Comm
This field displays the current state of the communication link
between the two controller cards.
OK
indicates that the cards are
communicating;
F
AILURE
indicates that the cards are not able to
communicate with each other. If there is only one card installed,
N
ON
-R
EDUNDANT
is displayed.
Condition Description
Network Both controller cards are installed and everything is
functioning properly. The unit is in full Network
Protection Mode.
Circuit Unit is in Circuit Protection Mode and everything is
functioning properly,
or
unit is in Network Protection Mode and a failure on
the network has occurred.
None One controller card is installed,
or
the unit is in Circuit Protection Mode and the
secondary card has failed.
For more information on the different types of Protection Modes, see
Chapter 7, Circuit and Network Redundancy.