ADTRAN 4200659L8 Switch User Manual


 
Chapter 9. Transaction Language 1 (TL1)
9-12 MX2800 STS-1 User Manual 61200659L1-1
REPT-EVT
indicates an informational event. Table 9-3 lists
possible autonomous messages for informational events.
REPT
ALM
EQPT
(cont’d)
404 (PS A)
405 (PS B)
MJ PWR NSA NEND Power Supply Failure
404 (PS A)
405 (PS B)
MJ PWR NSA NEND Power Supply Communication
Failure
404 (PS A)
405 (PS B)
MJ PWR NSA NEND Power Supply Low
404 (PS A)
405 (PS B)
MJ PWR NSA NEND Power Supply Charger Fail
404 (PS A)
405 (PS B)
CR PWR NSA NEND Power Supply Battery Low
404 (PS A)
405 (PS B)
MJ PWR NSA NEND Power Supply Temp High
404 (PS A)
405 (PS B)
CR PWR NSA NEND Power Supply Temp Critical
Table 9-2. MX2800 STS-1 Alarm Events (Continued)
AID Notification
Code
Condition
Type
Service
Affecting
Location Description
Table 9-3. MX2800 STS-1 Informational Events
AID Notification
Code
Condition
Type
Service
Affecting
Location Description
REPT
EVT
EQPT
501 TC TIM-P SA NEND STS-1 Receive J-Trace
Event
502 (Ctrl A)
503 (Ctrl B)
TC NORMAL NSA NEND Controller Card Inserted
502 (Ctrl A)
503 (Ctrl B)
TC SYNCSTAT
CHNG
SA NEND STS-1 Clock Status Event
502 (Ctrl A)
503 (Ctrl B)
TC RCVRY SA NEND STS-1 Clock Source Event
502 (Ctrl A)
503 (Ctrl B)
TC SYNCPRI SA NEND STS-1 PRI. Ext. Clock
Event
502 (Ctrl A)
503 (Ctrl B)
TC SYNCSEC SA NEND STS-1 SEC. Ext. Clock
Event