ADTRAN 1200214L1 Network Card User Manual


 
61200214L1-1 IQ Probe User Manual 19
Chapter 3. Operation
VT 100 Terminal Connection and Operation
To control the IQ Probe using a VT 100 terminal, follow this
procedure:
1. Set the IQ Probe baud rate to match the terminal through the
front panel (maximum rate is 38.4k). Select 1 CONFIG, then
4 CONTROL PORT.
2. Using the ADTRAN-provided VT 100 terminal adapter,
connect the COM port of a VT 100 compatible terminal or
equivalent to the eight-pin modular jack labeled CONTROL
on the rear of the IQ Probe. This connection is used for both
local and remote configuration.
3. Open the connection and press Enter repeatedly until the
Login Menu appears (Figure 3-3).
4. Select Local Login to configure the IQ Probe unit connected
to the terminal. Select Remote Login to configure a remotely
located IQ Probe unit. For remote applications, at the remote
DLCI prompt, enter the outgoing DLCI (see the following
note) by pressing 1, then Enter, entering the DLCI number,
and pressing Enter again. Next, select Begin Remote Session
by pressing 2 and Enter.
When entering the DLCI for a remote application, enter the DLCI
associated with the local unit that you are logged in to (not the far end
DLCI).
If the wrong DLCI is entered or a network problem exists, the screen
freezes at the Press any key to continue prompt. Press CNTL + L
twice to return the unit to the Login screen.
5. Enter the password. The factory default password is adtran.
The Main menu will appear (Figure 3-4).
6. Make selections by entering the number corresponding to
the chosen parameter. Press ESC to return to the previous
screen.