Chapter 8. Configuring Dial Backup Options
IQ Probe encounters a busy or reorder, it attempts to establish
the call the specified number of times. The factory default
setting is 5.
Wait to Redial (REDIAL DELAY)
This option works in conjunction with the preceding Redial
Counter. It selects the amount of time between redial attempts to
connect the backup line. The amount of time, which is manually
entered, can be up to 99 seconds. The factory default setting is
15 seconds.
DBU Card Configuration Options
The following selections are dependent upon the type of ESP
DBU card installed (if any). If no card is installed or if the ESP 4-
Wire SW56 card is installed, then the selections in this section do
not appear.
Modem Options
The Modem Options field is available when the ESP V.34 DBU
card is installed.
Tone/Pulse
Select the dialing method for the dial backup service.
ISDN Options
The ISDN Options field is available when the ESP ISDN DBU
card is installed.
Switch Type
Select which type of telco CO switch is providing the ISDN
service. There are four options for ISDN switch types:
Lucent 5ESS
DMS100
National
NEC