ADTRAN T1/FT1 Network Card User Manual


 
NetVanta T1/FT1 + DSX-1 Network Interface Module (NIM) P/N 1202863L1
For more detailed documentation, visit us online at www.adtran.com.
Quick Start Guide
®
Quick Start Guide, 61202863L1-13D, November 2006 Copyright © 2006 ADTRAN, All Rights Reserved
INSTALLATION INSTRUCTIONS
1. Remove the power from the unit.
2. Slide the option module into the option slot until the module is
firmly seated against the chassis.
3. Secure the pins at both edges of the module.
4. Connect the cables to the associated device(s).
5. Complete installation of the base unit.
6. Restore power to the unit.
For NetVanta modules with outside plant
connections, ensure that all cables are removed
from the module before installing or removing it
from the NetVanta chassis.
NetVanta modules should be installed only in NetVanta
Series products.
WAN-T1 NETWORK (RJ-48C) CONNECTION PINOUTS
Pin Name Description
1 R1 Receive data from the network - Ring 1
2 T1 Receive data from the network - Tip 1
3 Unused
4 R Transmit data toward the network - Ring
5 T Transmit data toward the network - Tip
6-8 Unused
DSX-1 (RJ-48C) CONNECTION PINOUTS
Pin Name Description
1 R Transmit data toward the DTE- Ring
2 T Transmit data toward the DTE - Tip
3 Unused
4 R1 Receive data from the DTE - Ring 1
5 T1 Receive data from the DTE - Tip 1
6-8 Unused
An optional Dial Backup Interface Module (DIM) is
required for dial backup applications.
For a description of the DBU pinouts, refer to the Quick
Start Guide included with your DIM shipment.
WAN-T1 DSX-1 DBU
SPECIFICATIONS
Operating
Modes
Frame Relay, Multilink Frame Relay,
PPP, Multilink PPP, HDLC
T1/FT1
Interface
Supported Standards: AT&T TR 62411, AT&T TR 54016,
Bellcore TR.194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 56/64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft
(short)
Connector: RJ-48C
DS0 Assignment: Programmable
DSX-1
Interface
Supported Standards: ANSI T1.102
Line Rate: 1.544 Mbps
DSX Receiver Input Range: -10 dBdsx to +6 dBdsx
Capacity: 1 to 24 DS0s
Line Codes: AMI, B8ZS
DSX-1 interface to PBX
Framing: D4 (SF) or ESF
Line Length: 0 to 655 ft and -7.5 dB
Connector: RJ-48C
Clock Source Network, internal, and through
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, 2
15
- 1,
2
20
- 1, all ones, all zeros
Network loopbacks (local and remote); responds to both
inband and FDL loop codes (T1 interface only)
Alarm generation and detection
Network and user sets of performance data (15 minutes
and 24 hours)
Compliance FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950
Physical Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing