AEG ARE I2 Computer Hardware User Manual


 
Manual
Page 21 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
e-mail: info@AEGID.de
7 Operating Modes of the Reader
There are two operational modes defined:
Mode 2 The reading process is triggered by an software command coming
from the serial interface.
Mode 0 Continuos read.
If there is an read/write transponder used, the serial number of
. the transponder is always read.
7.1 Mode 2 – Triggered by an Software Command
In operating mode 2, the exciter is always turned off. Triggered by the software command
(GT; RD ; WD), the exciter is activated. After successful reading or writing of a transponder
number the exciter is turned off automatically.
Figure 7.1.1- Software triggered reading operation
If the first reading cycle yields no result (NoRead), the on-time of the exciter is limited by
the parameter TOR (time out reader): Reading cycles are continuously started until either a
transponder is read successfully or the time span corresponding to the value of the pa-
rameter TOR has expired. The reader will not interrupt the last running readout cycle. If no
transponder number has been read, a NoRead is output.
exciter
processor
interface
reading cycle
ID
GT