Agilent Technologies Agilent E6474A Network Card User Manual


 
System Information C
Agilent E6474A User’s Guide 147
Power DC power jack 100 mils, positive center
Miscellaneous Operating temperature range 0°C to 55°C
Maximum relative humidity 80% for temperatures up to 31°C, decreasing
linearly to 50% relative humidity at 40°C
Storage temperature range – 40°C to +70°C
Dimensions 6 in x 3-5/8 in x 8 in
15.24 cm x 9.21 cm x 20.32 cm
Weight 4.6 lbs (2.1 kg)
Power
Power (internal GPS option 200)
9 to 34 V DC, 9W
9 to 34 V DC, 10W
AC Power 100 - 240 Volts AC
50 - 60 Hz
Internal GPS
(Option
200)
GPS Receiver 8 Channel internal GPS receiver
Connector type SMA
Differential compatible without dead reckoning
Note: Internal GPS is standard on all “C” receivers. It can be disabled if you wish to use an
external GPS system.
* It is recommended the input signal level not exceed – 40 dBm.
Adjacent channel desensitization applies to wideband mode (1.25 MHz IF filter) and is defined as: 1 dB compression of tuned
signal with interfering signal 1.25 MHz from tuned signal.
Receivers (with the exception of “C” receivers) fitted with an internal GPS do not support connection to external GPS receiv-
ers.
Item Description Specification