Agilent Technologies N2610A Network Card User Manual


 
Cable Testing in Expert Mode 5
The Expert Autotest Setup
Agilent FrameScope 350 User’s Manual 125
2 On the Autotest Setup screen, press Edit Settings. The Autotest
Settings screen shows a menu of parameters and functions.
3 Press the name of the probe, then press View. The Probe Information
screen displays, with information on the probe inserted in the
FrameScope.
4 If you desire to check the probe test count before each test, press
Check Probe Test Count and enter the limit to be tested against.
5 To view information on the probe installed in the DualRemote, press
the DualRemote tab. The Probe Information screen displays
information about the probe in the DualRemote after running an
Autotest.
6 If you desire to check the DualRemote probe test count before each
test, press Check Probe Test Count and enter the limit to be tested
against.
Setting Network Limits
The FrameScope 350 can determine compliance with signal to
noise ratio (SNR) requirements for a variety of popular LAN
technologies. To do this:
1 In Expert Mode, press Autotest on the Main Menu. The Autotest
Settings screen displays.
2 On the Autotest Setup screen press Edit Settings.
3 On the Autotest Settings screen press Network Limits. Then press
Edit.
4 On the Networks Setup screen press on the appropriate technology
for which you want to certify the tested cabling. A red check will
appear in each technology selected. Other includes a variety of
legacy network standards.