Agilent Technologies N2610A Network Card User Manual


 
132 Agilent FrameScope 350 User’s Manual
5 Cable Testing in Expert Mode
The Expert Autotest Setup
Setting the Maximum Frequency
The FrameScope 350 allows you to select the maximum range
for swept frequency measurements. The choices depend
somewhat on the standard selected previously, for example for
Category 6, the 100 MHz choice is not available. To set the
maximum frequency:
1 In Expert Mode, press Autotest on the Main menu.
2 On the Autotest Setup screen press Edit Settings. On the Autotest
Settings screen press Max Frequency. On the Frequency Setup
screen select the maximum frequency of the data being stored.
Setting the Plot Storage Requirements
Another storage choice is available, whether to save plots or
not. Saving plots stores the entire swept frequency
measurement. Summary data is the worst case value for each
test and is the minimum required for standards compliance. To
set the data being stored:
1 In Expert Mode, press Autotest on the Main menu.