Agilent Technologies N2610A Network Card User Manual


 
Cable Testing with the FrameScope 350 3
Cable Testing Overview
Agilent FrameScope 350 User’s Manual 59
Figure 9 Link Test Configuration
Figure 10 Channel Test Configuration
Cable Testing Procedure
The following steps describe the general procedure for
performing cable certification testing using the FrameScope
and DualRemote testers.
1 Calibrate the FrameScope and DualRemote testers that you
will be using. See page 61.
2 Choose a link or channel test configuration to meet your
application. See page 57.
FrameScope DualRemote
Telecommunications
Closet
User Location
Outlet
Link Probe Link Probe
Structured Cabling Link
FrameScope DualRemote
Telecommunications
Closet
User Location
Outlet
Channel Probe
User Patch
Cord
Structured Cabling Link
Channel Probe
User Patch
Cord