Agilent Technologies N2610A Network Card User Manual


 
Cable Testing with the FrameScope 350 3
Setting Up an Autotest
Agilent FrameScope 350 User’s Manual 73
4
Enter the pair count, cable construction, and impedance
(default selections are available) and press Next.
5 Enter the nominal velocity of propagation (NVP) for each
pair, if known, or select Calculate NVP from length. If you
need to calculate the NVP from length, attach at least 50 feet
of cable to the FrameScope with the far end disconnected,
enter the measured length, and press Calculate. The NVP as
a percentage of the speed of light will be supplied in the NVP
window. Press Next.
6 Select the target performance grade of the cable if known
and press OK. The Autotest Setup screen displays, with the new
cable type next to the cable spool icon.