Agilent Technologies N2610A Network Card User Manual


 
Cable Testing with the FrameScope 350 3
Using Talksets
Agilent FrameScope 350 User’s Manual 87
Using Talksets
The 2-Way Talkset Kit (N2605A-137) allows operators at opposite ends of
a copper cable run to coordinate their efforts.
To use talksets for communicating between the ends of a cable run:
1 Insert a talkset’s plug into the talkset jack on the FrameScope, and
the plug of another talkset into the jack of the DualRemote. See
“Talkset Port” on page 5, for the jack’s location.
2 Connect the FrameScope’s and DualRemote’s SmartProbes to the
ends of a cable run.
3 Speak and listen as with any telephone headset.
Talkset Controls
The FrameScope talksets have two controls:
The thumbwheel in the inside curve of the control housing
controls the earphone volume.
The switch on the outside curve of the control housing
switches the microphone off.