Agilent Technologies SMPTE 310M Network Card User Manual


 
9
MPEGscope Plus and MPEGscope Lite
Alternative
configuration
This configuration applies only if your MPEGscope is housed in a Kayak XU PC
(e.g., E6277B or E6277C). It enables you to have both the SMPTE 310M interface
and another optional line interface (e.g., the ASI & Serial ECL (DHEI) interface)
installed at the same time. The configuration requires repositioning all
MPEGscope cards into the first four slots, and replaces Steps 2 and 3 on pages 6
to 8. Follow all other steps as usual.
2
Remove the blank faceplate
and install the Real-time
Analyzer card into slot 1.
4
Install the optional line
interface (e.g., the ASI &
Serial ECL (DHEI) interface)
into slot 2.
3
Attach the IAB ribbon cable to
the MPEGscope main card then
install the card into slot 3.
7
Connect the ribbon cable from
the MPEGscope main card to the
Real-time Analyzer card.
5
Connect the IAB ribbon cable from
the MPEGscope main card to the
optional line interface (e.g., the ASI
& Serial ECL (DHEI) interface).
6
Install the SMPTE 310M
interface card into slot 4.
1
Remove the cards from slots 2, 3 and 4, disconnecting cables as necessary.