SMPTE 310M interface specifications
WARNING To ensure the Electromagnetic Compatibility (EMC) of MPEGscope, use shielded
cables on all interfaces.
Type Biphase mark
Maximum line rate 40 Mb/s
(Minimum receive and transmit rate is 16 Mb/s)
Timestamps Packet timestamp clock: 10 MHz +/- 5 ppm
Resolution of timestamp clock: 100 ns
Packet timestamp sampling is accurate to within +/- 1 timestamp clock period
between consecutive packets
Electrical Spec 800 mV pp (nominal)
Connector Type 75
Ω BNC
Standard SMPTE 310M Standard, Sept. 98
Part Number E6292A