Alcatel-Lucent 6600 Switch User Manual


 
OmniSwitch 6600 Family Chassis and Hardware Components Backup Power Supply
OmniSwitch 6600 Family Hardware Users Guide September 2006 page 2-29
Power Supply Redundancy
After a backup power supply is installed, the primary (factory-installed) power supply continues to take on
the full power load for switch operations. Meanwhile, the backup power supply operates in active standby
mode. If the primary power supply fails unexpectedly, the backup power supply automatically takes up the
full power load without disrupting the switch.
OS6602-BPS Backup Power Supply Specifications
Input Voltage 85 to 150 VAC
Input Frequency 47 to 63 Hz
Efficiency 75% measured at 115 VAC
Temperature Operating: 0 to +50 Celsius
Non-Operating: - 40 to +85 Celsius
Relative Humidity 5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude 10,000 feet @ +32 Celsius
OS6602-BPS-DC Backup Power Supply Specifications
Input Voltage 36 to 72 VAC
Input Frequency N/A
Efficiency 75% measured at 115 VAC
Temperature Operating: 0 to +50 Celsius
Non-Operating: - 20 to +85 Celsius
Relative Humidity 5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude 10,000 feet @ +32 Celsius
OS6600-BPS-P PoE Backup Power Supply Specifications
Width 15.50 inches, approx.
Height 2.61 inches, approx.
Height (rack units) 1.5 RU
Depth 4.53 inches, approx.
Ambient Temperature 0 to +70 deg C, operating;
-40 to +85 deg C, non-operating
Humidity 5% to 90% Relative Humidity (Operating)
0% to 95% Relative Humidity (Storage)
Altitude 10000 feet at +32 deg C, operating; 50000 feet, non-operating