OmniSwitch 6600 Family Chassis and Hardware Components Console Port
OmniSwitch 6600 Family Hardware Users Guide September 2006 page 2-62
Console Port
The console port, located on the chassis front panel, provides a serial connection to the switch and is
required when logging into the switch for the first time (refer to the OmniSwitch 6600 Family Getting
Started Guide for more information). By default, this connector (a female DB-9 on OmniSwitch 6624 and
6648 switches and an RJ-45 port on OmniSwitch 6600-U24, 6600-P24, 6602-24, and 6602-48 switches)
provides a DCE console connection.
Serial Connection Default Settings
The factory default settings for the serial connection are as follows:
Modifying the Serial Connection Settings
If you wish to modify the default serial connection settings (i.e., baud rate, parity, data bits, and stop bits),
refer to the following steps.
Note. You must be connected to the switch via the console port before attempting to change serial connec-
tion settings. Otherwise, an error message will display. In addition, if you are changing console port
settings for switches in a stack, console port settings must be identical on all switches. Before configuring
the console port settings for a stack, make sure each switch is operating in either primary or secondary
status (you may be required to disconnect switches within the stack before beginning).
1 Enter modify boot parameters at the CLI prompt. The boot prompt displays:
Boot >
2 To change the baud rate, enter boot serialbaudrate, followed by the desired baud rate value. Options
include 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 76800, and 115200. For example:
Boot > boot serialbaudrate 19200
Note. Setting the console port to speeds above 9600 baud can cause problems with Zmodem uploads.
3 To change the parity value, enter boot serialparity, followed by the desired parity value. Options
include none (default), even, and odd. For example:
Boot > boot serialparity even
baud rate 9600
parity none
data bits (word size) 8
stop bits 1
X-ON/X-OFF enabled