Alcatel-Lucent 6600 Switch User Manual


 
OmniSwitch 6600 Family Chassis and Hardware Components Viewing Basic Chassis Information
OmniSwitch 6600 Family Hardware Users Guide September 2006 page 2-69
Basic Primary Slot and Component Information
To view basic slot and component information for the base chassis only (i.e., no installed uplink or stack-
ing modules), enter the show cmm command at the CLI prompt. This command displays the following
information:
Model name, also referred to as chassis type
Chassis description
Alcatel part number
Hardware revision level
Serial number
Manufacture date(s)
Current power and operational status
Base chassis MAC address
ASIC and firmware information
For example:
-> show cmm
CMM in slot 1
Model Name: OS6648 ,
Description: 48PT 10/100 Stack,
Part Number: 902098-10,
Hardware Revision: 210,
Serial Number: 2313283p,
Manufacture Date: FEB 05 2106€,
Firmware Version: N/A,
Admin Status: POWER ON,
Operational Status: UP,
Power Consumption: 40,
Power Control Checksum: 0x0,
MAC Address: 00:d0:95:12:ed:00,
ASIC - Physical:
For complete descriptions of the command output, refer to the OmniSwitch CLI Reference Guide.
Stacked Configurations. You can use the show cmm command to display information for all switches in
a stack, or for a specified switch only. When the show cmm syntax is entered with no specified slot
number, information for all switches displays. When a slot position is specified in the command line
(e.g., 3), information displays for the corresponding switch only. For detailed information on stacked
OmniSwitch 6600 Family switches, refer to Chapter 4, “Managing OmniSwitch 6600 Family Stacks.”