Alcatel-Lucent 6600 Series Switch User Manual


 
Removing MiniGBICs OmniSwitch 6600 Series Chassis and Hardware Components
page 2-36 OmniSwitch 6600 Series Hardware Users Guide April 2004
2 Push the MiniGBIC into the slot until it is completely inserted and securely seated in the
OS6600-GNI-U2 module on OmniSwitch 6624, 6600-U24, and 6648 switches, as shown.
Installed MiniGBIC (OS6648 Shown)
Removing MiniGBICs
MiniGBICs modules can be hot swapped. You are not required to power off the switch before removing a
MiniGBIC from the uplink module. To remove a MiniGBIC from the uplink module, follow the steps
below:
Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding
strap, or by grounding yourself properly. Static discharge can damage the MiniGBIC, as well as the switch
and uplink module.
1 On OmniSwitch 6624, 6600-U24, and 6648 switches only, make sure that the captive screws on the
OS6600-GNI-U2 are tightened and the module is securely installed in the chassis.
2 There is a small removal handle at the front of the MiniGBIC transceiver. Carefully lift this handle;
then, grasp the handle and carefully pull the MiniGBIC from the module.
3 Store the MiniGBIC in a secure, static-free location. Placing the MiniGBIC in an anti-static bag is
recommended.
EXPANSION/STACKING
5
1
5
2