Allied Telesis AR44xS series Switch User Manual


 
Features in 276-04 17
Version 276-05
C613-10474-00 REV D
CR00013083
TACACS+, User 2 After a very large number of successful logins via TACACS+ authentication, the
router or switch would reboot.
This issue has been resolved.
Y - YYYYY- - -
CR00013096
CR00013718
IPv6 2 When the router or switch learned a better IPv6 route to exactly the same
destination as an existing route, the router or switch did not always change
existing data flows so that they used the new route. This meant that existing
flows did not always follow the optimal path.
This issue has been resolved. When the router or switch learns a better IPv6 route,
both new and existing flows now use it.
Also, the commands create ipv6 interface and set ipv6 interface now include
a new parameter: metric. This allows you to set the RIP metric of link local
interfaces to a desired value. Note that the metric parameter is only valid on link
local interfaces.
Y -YYY--- - -
CR00013234
IP Gateway 2 If the router or switch attempted to email log output, and used a domain name
server that gave a non-standard response to the DNS query, the router or switch
sometimes rebooted.
This issue has been resolved.
Y - YYYYY- - -
CR00013276
UPnP 2 In UPnP, Msearch requests were stored indefinitely, which eventually exhausted
the router’s memory and caused it to reboot.
This issue has been resolved. Msearch requests are now deleted once the router
has finished with them.
Y -Y----- - -
CR00013309
L2TP 2 When an L2TP LAC Client (for example, a Microsoft Windows XP VPN Client)
activated an L2TP tunnel to a router or switch that was operating as an LNS, the
dynamic PPP interface on the LNS left out the PPP authentication phase.
This also prevented the interface from obtaining an IP address by remote IP
assignment from a User Database entry.
This issue has been resolved.
Y -YYY--- - -
CR Module Level Description
AR44xS/ AR450S
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800