Allied Telesis AR44xS series Switch User Manual


 
Features in 276-04 19
Version 276-05
C613-10474-00 REV D
Level 3
CR Module Level Description
AR44xS/ AR450S
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800
CR00008192
Switch 3 The following issues occurred with the counters that are displayed by the show
interface=port-number counter command:
If a switch port received a broadcast or multicast packet with an error (such as
a bad CRC error), the ifInUcastPkts counter—the number of unicast packets
received— was incremented. This issue has been resolved.
On AT-9800 series switches, the ifInErrorOctets counter is a count of packets,
not octets. Therefore, this counter has been renamed to ifInErrors.
- --YYYY- - -
CR00010345
Firewall 3 When the HTTP proxy URL filter had entries that allowed certain domains and
also had entries that denied certain keywords, the supposedly-allowed domains
were denied if they contained the denied keywords. The proxy allowed the page
/index.html from such domains, but no other pages.
This issue has been resolved. The proxy no longer checks allowed domains
against the keyword list.
Y -YYY--- - -
CR00010504
IP Gateway 3 When a VRRP master was configured with VRRP adoption enabled, pings from
the VRRP master to its own VR IP address failed.
This issue has been resolved.
Y - YYYYY- - -
CR00011444
Asyn 3 If information was sent to a console (asyn) port that had no cable plugged into
it, excessive CPU usage occurred.
This issue has been resolved.
Y - YYYYY- - -