Switch 2 Previously, when 300 MAC address filters were added to a port and the port was
reset, the CPU became 100% utilised.
This issue has been resolved.
---YYYY- - -
CR00008992
IPv6 2 The router or switch sometimes unexpectedly stopped forwarding IPv6 multicast
traffic if the multicast’s upstream path changed. This could occur, for example,
when the path changed because an interface went down.
YYYYY- - YYY
CR00009201
ARP 2 An ARP timeout caused the removal of the ARP entry, resulting in packet loss until
the entry was re-added.
This issue has been resolved.
YYYYYYYYYY
CR00009280
ATM 2 When the router was using IPsec and either IPoEoA or IPoA, and it received traffic
from a VLAN at a higher rate than it could transmit over the ADSL link, eventually
the ATM interface would intermittently stop transmitting traffic.
This issue has been resolved.
Y---------
CR00009283
Switch 2 If a 48-port switch learned many thousands of MAC addresses, it rebooted when
the addresses timed out.
This issue has been resolved.
---YYYY- - -
CR00009539
IP Gateway 2 The IP DNS cache feature was not designed to include MX (Mail Exchange) DNS
records. In some circumstances, MX DNS entries were added to the IP DNS cache
and the name of a DNS record was incorrectly associated with the IP address of
the MX entry. This stopped the router or switch from correctly resolving A-record
requests for the affected domain name.
This issue has been resolved by ensuring that MX entries are never added to the
IP DNS cache.
YYYYYYYYYY
CR00010265
Switch 2 When the ingress and egress port were defined in an Layer 3 filter with an action
of deny, the filter denied the traffic to be sent out all the egress ports and not
just the egress port specified in the filter.
This issue has been resolved.
---YYYY- - -
CR Module Level Description
AR44xS / AR450S
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800