Allied Telesis AR44xS series Switch User Manual


 
Features in 276-02 34
Version 276-05
C613-10474-00 REV D
CR00011349
SYN 2 At low baud rates, a synchronous connection was unable to reach 100%
utilisation of the available bandwidth. The queueing mechanism has been
improved to allow 100% link utilisation. Flag sharing between back-to-back
HDLC frames is now supported for synchronous connections.
YYYY------
CR00011396
PIM on IPv6 2 When a user specified a static RP candidate and saved the configuration with the
create config command, the resulting configuration file did not include the RP
candidate. Therefore, rebooting the router or switch deleted the static RP
candidate entry.
This issue has been resolved.
YYYYY- - YYY
CR00011411
PoE 2 When multiple telnet sessions where open on the AT-8624PoE switch, and the
command show switch port was entered, the switch command line became
unresponsive for several minutes.
This issue has been resolved.
-----Y----
CR00011586
Switch 2 When a port is no longer a member of any VLAN as an untagged port, it would
discard received untagged BPDU packets.
Note that this issue only occurred on AT-8900 and AT-9900 switches; other
switches already correctly handled untagged frames on tagged ports when
required.
This issue has been resolved.
-------YY-
CR00011587
Switch 2 Previously, if a port was a tagged member of a VLAN, it was not able to transmit
untagged frames to that VLAN.
This issue has been resolved. When required, STP BPDUs can now to be sent
untagged out a port, even if the port is configured as a tagged member of a
VLAN.
-------YY-
CR00011645
Switch 2 After an AT-8800 series switch was powered down or rebooted, non auto-
negotiating copper GBICs did not correctly handle Ethernet PAUSE frames.
This issue has been resolved.
----Y-----
CR Module Level Description
AR44xS / AR450S
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800