Asyn 3 When the router sent a continuous stream of data over a permanent assignment,
and the ASYN port at the receiving end of the tunnel was significantly slower
than the ASYN port at the sending end, the sending router eventually rebooted.
This was because the router had to queue packets and eventually ran out of
memory.
This issue has been resolved. The router now stops receiving ASYN data when
memory is low, so its queue does not get too full.
YYY- ------
CR00012359
Switch 3 You can now return the description of a switch port to its original blank value by
entering the following command:
set switch port=port-number description=
and providing no value for the description parameter.
Y- YYYYYYYY
CR00012413
Logging 3 When a user creates permanent log filters, the existing default filter is moved to
the bottom of the list of filters, instead of being deleted. This behaviour is correct.
However, output of the command show config dyn=log previously included
commands to delete the default filter then add it back in, which was confusing.
This issue has been resolved. The output of the command show config dyn=log
now only includes the default filter if the user has specified the default filter in a
command. To see all existing filters, use the command show log
output=permanent full.
- Y- YY- YYYY
CR00012427
Logging 3 If a user modified the permanent log by destroying it and creating a new one,
and then saved the configuration with the command create config, the
resulting configuration file included the command destroy log
output=permanent. Therefore when the router or switch restarted it destroyed
the log and all entries.
This issue has been resolved. The command create config now writes the
command set log output=permanent to the configuration file instead of the
destroy and create commands.
- Y- YY- YYYY