Allied Telesis AR44xS series Switch User Manual


 
Features in 276-04 6
Version 276-05
C613-10474-00 REV D
Features in 276-04
Software Maintenance Version 276-04 includes all resolved issues and enhancements in earlier versions, and the resolved issues and enhancements in the
following tables. In the tables, for each product series:
“Y” in a white column indicates that the resolution is available in Version 276-04 for that product series.
“-” in a white column indicates that the issue did not apply to that product series.
a grey-shaded column indicates that Version 276-04 was not released on that product series.
“-” in a grey column indicates that the issue did not apply to that product series.
“Y” in a grey column indicates that the issue applied to that product series. These issues are resolved in the next Version (276-05).
Level 1
CR Module Level Description
AR44xS/ AR450S
AR7x5
AR750S
Rapier i
AT-8800
AT-8600
AT-8700XL
AT-8948
AT-9900
AT-9800
CR00007273
Switch 1 If a user created a configuration file that contained port trunk settings before
VLAN port settings, then a loop occurred when the switch rebooted with this
configuration.
This issue has been resolved.
- - - YYYY- - -
CR00011711
PIM v6 1 For IPv6, the router or switch could restart when PIM-SM detected that the
primary RPF interface to an (S,G) routing entry had changed because the RPF
interface had gone down. When the interface went down, PIM-SM recalculated
the RPF to the source for the (S,G) entry, and if PIM-SM only found a non-PIM
neighbour as the RPF to the source for the (S,G), the router or switch could
restart.
This issue has been resolved.
Y - YYY- - - - -