APC ES 350 Power Supply User Manual


 
Back-UPS ES 350/500
User’s Guide
1
2
3
Connect Battery
Connect
Equipment
Power On and
Install Software
990-9197 Revision 1 11/01 Copyright © 2001 American Power Conversion Corp.
All other trademarks are property of their respective owners.
The Back-UPS ES is shipped with one battery wire disconnected in compliance with Department of Transportation (DOT) regulations. The Back-UPS ES
will not operate until the wire is connected to the touch safe battery terminal.
NOTE: Small sparks may occur during battery connection. This is normal.
1
2
4
TURN the Back-UPS ES over and
remove the battery compartment
cover screw using a flat blade or
phillips-head screwdriver.
Slide the battery
compartment cover
completely off of
the Back-UPS ES.
Replace the battery,
battery compartment
cover and cover
retaining screw.
Surge Protection
These outlets provide full-time protection from surges even if
the Back-UPS ES is switched OFF. Plug your printer, fax
machine, scanner, or other peripherals that do not need
battery power into these outlets.
Battery Back-up plus Surge Protection
These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer, monitor,
and one other data-sensitive device (external disk or tape
drive) into these outlets.
Connect FAX/Modem/Phone
Back-UPS ES protects a single
line (2-wire) fax, modem or
phone from surges when it is
connected through the Back-
UPS ES as shown.
Place the Back-UPS ES to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly
into a wall outlet; not a surge protector or
power strip.
Connect Computer Cable
The supplied cable and software provide
automatic file saving and shutdown of the
operating system in the case of a sustained
power outage.
Connect the cable to the Data Port of the Back-
UPS ES. Connect the other end of the cable to
the USB port on your computer. The software will
automatically find the USB Port of your
computer.
Press the ON/OFF switch to power the unit
ON.
A single short beep and the green “Power On”
indicator confirms that Back-UPS ES is on and
ready to provide protection.
The Back-UPS ES should charge for at least
16 hours to ensure sufficient runtime. The unit
is being charged whenever it is connected to
utility power, whether the unit is turned ON or
OFF.
If the red Building Wiring Fault indicator
(located on the end near the power cord) is lit,
your building wiring presents a shock hazard
that should be corrected by a qualified
electrician.
Install the PowerChute Personal
®
Edition
software
Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.
3
LIFT the battery out of the compartment and connect the
black wire to the battery terminal.
www
.apc.com
®
Power On
Battery Backup plus Surge Protection
Wall Outlet
Modem/Phone/Fax
Computer
USB Port
Surge Protection
Back-UPS ES 500
Back-UPS ES 350
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
Status Visual Indications Audible Indication Alarm Terminates
When
On Line - UPS is supplying conditioned
utility power to the load
Power On LED - ON None n/a
On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets
Power On LED - ON
(off during beep)
Beeping 4 times
every 30 seconds
UPS transfers back to
On Line operation, or
when UPS is turned
off.
Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhuastion
Power On LED -
Flashing
Rapid beeping (one
second intervals)
UPS transfers back to
On Line operation, or
when UPS is turned
off.
Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected
Power On LED -
Flashing
Constant tone UPS turned off with
the power switch.
Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.
Power On LED - OFF Constant tone UPS turned off with
the power switch.
Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.
Power On LED - OFF Beeping once every
4 seconds
UPS transfers back to
On Line operation, or
when UPS is turned
off.
Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.
Building Wiring Fault
LED (red) - ON
None UPS is unplugged, or
plugged into a
properly wired outlet.
Status Indications
Power On
Circuit
Breaker
AC Line
Cord
Building Wiring
Fault Indicator
UPS Power
On Indicator
Power
Switch
®
See the Troubleshooting section for additional assistance.
Sold by:
http://www.TWAcomm.com
Toll Free: (877) 892-2666