AT&T 3551 Switch User Manual


 
COMSPHERE 3550 Series Data Service Units
C-4 February 1995 3550-A2-GB20-10
Table C-3
(2 of 3)
Device Health and Status Messages
Message Condition
Dial Tone:Fail Dial tone test was enabled and test failed.
DDS F:
alarm
Digital facility alarm;
alarm
is one of the following network alarms:
BiplrViol Excessive Bipolar Violations
Fac Alarm Facility Alarm
OutofServc Out-of-Service condition
No Signal No signal has been received
DSU:Device Fail Internal failure in the DSU is detected. (Go to the Test branch for Device Test.)
DSU:Disable DSU transmitter is disabled. (Go to the Control branch to enable the DSU.)
DSUTst:
test
,
init
The DSU is running a test, initiated from
init
.
test
is one of the following tests:
BERT Bit Error Rate Test
BiL Bilateral Loopback
Dev Device Test
DL Digital Loopback
DT Digital Test
DTE DTE Loopback
E-E End-to-End Test
Lamp Lamp Test
NetL Network Loopback
RL Remote Digital Loopback
TM Test Mode
init
is one of the following initiators:
DTE Data Terminal Equipment
FP Front Panel (the DCP)
NMS Network Management System
Ntwk Network
Remt Remote DSU
External Alarm A The DSU detects a positive voltage on Pin 23. This alarm condition is defined by the
Ext Leads configuration option.
External Alarm B The DSU detects a positive voltage on Pin 19. This alarm condition is defined by the
Ext Leads configuration option.
Invalid Address A DSU was powered up with an invalid address. Invalid addresses are:
0 This is reserved for the SDU
192 This is reserved for the broadcast address
191 Invalid for a DSU with a DBM because of the reserved 192
broadcast address
255 Invalid for a DSU with a DBM