7-4
Chapter 7
Cajun P550/P880/P882 Switch User Guide
Figure 7-3. Switch Fabric Status Dialog Box
Enabling Redundant Hardware
6. You can enable the redundant hardware from either the Web
Agent or the CLI. After you enable redundant hardware, the
applicable redundant component takes over if either the
primary controller or element fails.
Enabling Redundant Hardware Using the Web Agent
To enable the redundant hardware using the web agent:
1. Select Yes from the Configure redundant Hardware field
pull-down menu on the Switch Fabric Status dialog box
(Figure7-3).
2. Click APPLY. The redundant hardware is enabled. Enabling
Redundant Hardware Using the CLI
To enable the redundant hardware using the CLI, enter the
following command from Priv Configure mode:
> set fabric configure-redundant-hardware enable
Refer to the Avaya™ P550™/P880/P882 Command Line Interface
Reference Guide for Version 5.0 for details about this command.