Cajun P550/P880/P882 Switch User Guide
Monitoring the Cajun Switch
17-9
Figure 17-5. Protocol Event Management Dialog Box
5. Refer to Table17-3 to configure the Protocol Event
Management dialog box parameters for the specific protocols
that you have configured on your switch:
6. Click APPLY to save your changes, or CANCEL to restore
previous settings.
Table 17-3. Protocol Event Management Dialog Box Parameters
Column
Heading
Parameter
Fault Select Enable to display serious errors that can cause
a system crash, for example, panic. The default is
Disable.
Error Select Enable to display serious errors that will not
cause a system crash but can contribute protocol
problems.
Warning Select Enable to display non-critical errors. The
default is Disable.
Info Select Enable to display Event details. The default is
Disable.
Trace Select Enable to display RIP and OSPF packet tracing.
The default is Disable.
Debug Select Enable to display event messages used to
troubleshoot a network problem. The default is
Disable.