Chapter 5: CCM Appliance Commands 71
Methods on page 30, Enabling plain text Telnet and SSH connections on page 23 and Using
security lock-out on page 32.
When you enter this command, you are prompted to confirm or cancel the specified information.
Access right: SCON
Access level: APPLIANCEADMIN
Syntax
SERVER SECURITY [AUTHENTICATION=<auth>] [ENCRYPT=<conns>]
[LOCKOUT=<hours>]
Server Set command
The Server Set command changes CCM appliance address settings. You may specify one, two or
all three parameters. A reboot is required if you change the IP address.
Access right: SCON
Access level: APPLIANCEADMIN
Syntax
SERVER SET [IP=<ip_address>] [MASK=<subnet>] [GATEWAY=<gtwy>]
Table 5.19: Server Security Command Parameters
Parameter Description
AUTHENTICATION=
<auth>
Authentication method. You may specify multiple values (other than None),
separated by commas. Valid values are:
LOCAL Use the local CCM user database to authenticate users.
RADIUS Use the previously defined RADIUS server(s) to authenticate users.
NONE Do not authenticate users. This method cannot be used when SSH
access is enabled, and it cannot be combined with other
authentication methods.
Default = LOCAL
ENCRYPT=<conns>
Enables/disables plain text Telnet or SSH connections. You may enable both by
specifying both values, separated by a comma. Valid values are:
SSH Enables SSH connections.
None Enables plain text Telnet connections.
Default = None
LOCKOUT=<hours>
Enables or disables security lock-out. To enable, specify the number of hours in the
lock-out period, in the range 1-999. To disable, specify a zero value.
Default = 0 (disabled)
Table 5.20: Server Set Command Parameters
Parameter Description
IP=<ip_address> IP address.