Avocent CCM1640 Network Card User Manual


 
58 CCM840/1640 Installer/User Guide
Port Set command
The Port Set command changes CCM port settings in the CCM configuration
database. At least one keyword parameter and value must be specified. For more
information, see Configuring Serial Port Settings in Chapter 3.
Access right: SCON or PCON
Access level: ADMIN or APPLIANCEADMIN
Syntax
PORT [<port>|ALL] SET
[TD=<device>] [NAME=<name>] [BAUD=<baud>] [SIZE=<size>]
[PARITY=<parity>] [STOP=<stopbits>] [FLOW=<signal>]
[TIMEOUT=<time-out>] [SOCKET=<socket>] [CHAR=^<cli_char>]
[TOGGLE=NONE|DTR] [POWER=<signal>]
Port Set Command Parameters
Parameter Description
<port>|ALL Either a port number in range 1-8 for a CCM840 or 1-16 for a
CCM1640, or All which indicates that the settings that follow should
be applied to all ports.
Default = port to which you are attached
TD=<device> Target device type. Valid values are Console and SPC. The SPC
value is reserved for future functionality.
Default = Console
NAME=<name> Port name, up to 32 characters. If the name contains spaces, enclose
the name in double quotes. To return one or all port names to default
values, specify Name=“”. The port name is used only by AVWorks.
Default = last 3 octets of MAC address plus the port number
BAUD=<baud> Baud rate. Valid values are:
0, 75, 110, 134, 150, 200. 300, 600, 1200, 2400, 4800, 7200,
9600, 14400, 19200, 28800, 38400, 57600, 115200.
Default = 9600
SIZE=<size> Number of data bits per character. Valid values are 7 and 8.
Default = 8
PARITY=<parity> Parity. Valid values are:
None No parity.
Even Even parity.
Odd Odd parity.
Mark Mark parity.
Space Space parity.
Default = None
STOP=<stopbits> Number of stop bits per character. Valid values are 1 and 2.
Default = 1