Chapter 5: CCM Commands 59
Port Set Command Parameters (Continued)
Parameter Description
FLOW=<signal> Flow control signal. For hardware ow control, be sure the control
signals are correctly wired, or data loss may occur. The ow control
signal cannot also be used for power status monitoring. Valid values are:
XONXOF Software XON/XOFF ow control.
RTSCTS Hardware RTS/CTS ow control.
DTRDCD Hardware DTR/DCD ow control.
None No ow control.
Default = None
TIMEOUT=<time-out> Number of time-out minutes in the range Ø-90. If no data is received
or transmitted during a Telnet session for the speci ed period, the
session will time-out. A zero value indicates no time-out. This value
overrides the time-out value set with a Server CLI command.
Default = use value set with Server CLI command
SOCKET=<socket> TCP port that must be entered on the Telnet client to connect to this
serial port. The new value becomes effective upon the next connection
to the port. When SSH is enabled, the CCM automatically adds 100
to the speci ed value.
When All is speci ed, port 1 will be assigned the speci ed socket
value plus 1, port 2 will be assigned the speci ed value plus 2, and
so on. When All is speci ed and SSH is enabled, port 1 will be
assigned the speci ed socket value plus 101, port 2 will be assigned
the speci ed value plus 102, and so on.
When both plain text Telnet and SSH connections are enabled, the
+100 value will not appear in displays.
Default = 3000 plus the port number, 3100 plus the port number if
SSH is enabled; see above for action taken if All is speci ed
CHAR=^<cli_char> CLI access character in the range A to _ (underscore) or NONE.
(The allowable ASCII range is Øx41-Øx5F and Øx61-Øx7A.) The
CLI access character, when pressed simultaneously with the Ctrl
key during a session with an attached serial device, will suspend
the session with the device and place you in CLI command mode. If
None is speci ed, the value speci ed in the Char parameter of the
Server CLI command will be used.
Default = None
TOGGLE=NONE|DTR When set to DTR, the CCM will toggle the ports DTR-out signal
off for 1/2 second each time a connection is made to the port. This
toggle is required to awaken the console port of some devices.
POWER=<signal> Control signal to monitor and the state that indicates the target
device has power on. The entire value must be speci ed;
abbreviations are not allowed. The power status monitoring signal
cannot also be used for ow control. Valid values are:
None Disables power status monitoring.
HICTS CTS high indicates power on.
LOCTS CTS low indicates power on.
HIDCD DCD high indicates power on.
LODCD DCD low indicates power on.
HIDSR DSR high indicates power on.
LODSR DSR low indicates power on.
Default = None