46 CCM4850 Installer/User Guide
Table 5.8: Port Set Command Parameters
Parameter Description
<port>
A port number in the range 1-48, a range of port numbers separated by a dash,
multiple port numbers separated by commas or CON.
Default = port to which you are attached
ALL
Indicates that the port settings that follow should be applied to all ports except the
console port.
TD=<device>
Target device type. Valid values are Console and SPC. The SPC value is reserved
for future functionality.
Default = Console
NAME=<name>
Port name, up to 32 characters. If the name contains spaces, enclose the name in
double quotes. To return a port name to its default value (last three octets of the
MAC address plus the port number), specify Name=“”.
Default = last 3 octets of MAC address plus the port number
BAUD=<baud>
Baud rate. Valid values are: 75, 110, 134, 150, 200. 300, 600, 1200, 2400, 4800,
7200, 9600, 14400, 19200, 28800, 38400, 57600 and 115200.
Default: = 9600
SIZE=<size>
Number of data bits per character. Valid values are 7 and 8.
Default = 8
PARITY=<parity>
Parity. Valid values are:
None No parity.
Even Even parity.
Odd Odd parity.
Mark Mark parity.
Space Space parity.
Default = None
STOP=<stopbits>
Number of stop bits per character. Valid values are 1 and 2.
Default = 1
FLOW=<signal>
Flow control signal. For hardware flow control, be sure the control signals are
correctly wired, or data loss may occur. The flow control signal cannot also be used
for power status monitoring. Valid values are:
XONXOF Software XON/XOFF flow control.
RTSCTS Hardware RTS/CTS flow control.
DTRDCD Hardware DTR/DCD flow control.
None No flow control.
Default = None
TIMEOUT=<time-out>
Number of time-out minutes in the range 0-90. If no data is received or transmitted
during a Telnet session for the specified period, the session will time-out. A zero
value indicates no time-out. The new value does not affect an active session; it takes
effect in subsequent sessions. This value overrides the time-out value set with a
Server CLI command.