NOTES: 1) IRISES, EAGLES, AND MICROCELL WILL OPERATE WITH THE 24VAC ON THE C3938 POWER SUPPLY CN3.
2) EAGLES ARE REQUIRED FOR SECONDARY ACTIVATION PER ANSI A156.10
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG TUC
80.0097.02
SCALE: DATE:
NONE 13 OCT 2005
PART NO:
SHEET
1 OF 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
INTERIOR SW
EXTERIOR SW
COMMON
SAFETY BEAM
COMMON
TOGGLE SW
COMMON
CLS MON SW
COMMON
PARTIAL OPEN
2WAY/ 1 WAY
NIGHT SW
COMMON
DAY/NITE SW
+24VDC
+ 24VDC
C2150 CONTROL
24 V
TRANSFORMER
INTERIOR
EAGLE
EXTERIOR
EAGLE
RA WH 1
RA BL 2
EA WH 3
EA BL 4
5 NC
4 NO
3 COM
2 12-24 VAC/DC
1 12-24 VAC/DC
RB WH 1
RB BL 2
EB WH 3
EB BL 4
* RECEIVER (A), EMITTER (A)
RECEIVER (B), EMITTER(B)
WH= WHITE, BL= BLACK
MICROCELL ONE
ON
1 2 3 4
INTERIOR
PUSHPLATE
EXTERIOR
PUSHPLATE
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
EXTERIOR IRIS