Brother QL-500 Printer User Manual


 
CHAPTER 4 CONTROL PANEL
4–17
Basic Operation Procedures
When you operate the MODE switch, remember the following basic steps:
1. Press the SEL switch to set the printer off-line.
2. Press the MODE switch to enter the MODE menus.
The first mode menu appears on the display.
INTERFACE MODE
Press the or switch to scroll through the menus forward or
backward. (Pressing the MODE switch allows forward scroll.)
INTERFACE MODE or FORMAT MODE
or RESOLUTION MODE or
Press the SET switch to enter the next lower menu level of the
selected menu.
Mode Menu SET Setting Menu SET Sub-Setting Menu
Press the or switch to select the setting on the display.
I/F=PARALLEL or I/F=RS-232C or
I/F=OPTION or
Press the SET switch to make the selected setting effective. Then
you move to the next selection or exit to the upper menu level.
When you see “exit” and press the SET switch, you can exit from
the current level of menu to the next higher level of the menu.
3. Advance to “exit MODE” and press the SET switch to exit from the
mode menus to the off-line ready state.
Pressing the SEL switch any time in any level of the menus allows you
to exit from the mode menus to the on-line state. The settings you have
made with the SET switch before exit are effective.