Chapter 3 Conversion: Install Components, Cover, and Front Bezel
21
Reorient the Control Panel
The control panel must be repositioned to be easily readable in the rack-mount
position. Reposition the control panel and its bezel, as follows:
1. Unscrew the two screws securing the control panel to the chassis.
2. Unhook the control panel from the face of the chassis, as shown in
Figure 3-2. A ribbon cable still connects it to the NetServer.
Control Panel
Lock Pawl
Figure 3-2. Detach Control Panel from NetServer Chassis
3. Remove the lock pawl by squeezing the base until the tabs disengage from
the mounting slots, as shown in Figure 3-2. The lock pawl is not used on
the rack-optimized configuration of the NetServer.