Cambex Bus Adapter Network Card User Manual


 
sw_fc_class (3) Fibre channel class.
devtype_exclude ( ) List of SCSI device types to ignore during
configuration. For example, specifying "1,5" would exclude
both tape and CD devices.
Attributes only used in loop mode include:
id (0) Default L_ID for adapter. See table of L_ID to ALPA.
login_on_lip (yes) Full login if LIP occurs.
full_duplex (no) Use full duplex loop open, OPNyx.
Generate Error Report
Accesses the AIX error logging facility.
Trace Cambex FC Adapters
Runs the AIX trace facility, looking only for the entries specific
to the adapter driver.
Path Management Commands
The path management commands available in SMIT are in the
devices menu under Cambex Dynamic Path Management:
List all Cambex Dynamic Paths
This provides the information on all paths and devices known to
the DPF driver. Use this when installing to verify that all paths
have been found and configured.
Change / Show Characteristics of a Cambex Dynamic Path
Displays the current path status and allows the user to place
paths online/offline or to change path preferences.
18