Cambex Bus Adapter Network Card User Manual


 
Troubleshooting
Use the errpt command to identify the cause of failure. The
lsdev command will provide the location of the component. For
example, if errpt identifies a loose cable on device hdisk1, lsdev
will give an address similar to:
hdisk1 Available 00-02-01 Cambex SCSI...
and lsattr -El hdisk1 will show:
clr_q no Device CLEARS it’s
Queue on error
location Location Label
lun_id 0x0 Logical Unit Num ID
node_name 0x20000080e511b744 FC Node Name
pvid none Physical Volume id
q_err yes Use QERR bit
q_type simple Queuing TYPE
queue_depth 16 Queue DEPTH
reassign_to 120 REASSIGN time out
rw_timeout 30 READ/WRITE timeout
scsi_id 0x0 SCSI ID
start_timeout 60 START UNIT timeout
ww_name 0x23000080e511b744 FC World Wide Name
Which indicates that the adapter is in card location 00-02, and the
drive is at SCSI ID 0, LUN 0.