Citizen Systems CBM-290 Printer User Manual


 
CBM-290/291 User’s Manual
28
CITIZEN
When the values set in m (bit image mode) are out of the above range, the data following after n1 is
processed as normal printing data.
After completion of bit image printing, printer returns to normal data processing mode.
(9) Specifying/ Canceling Underline (ESC - n)
Code: [1B]h + [2D]h + n
*{0n 02} data is described in Hex code.
Specifying/canceling an underline.
An underline is attached to the full character width. It is, however, not attached to the part
having been skipped by horizontal tab command.
An underline is not attached to a 90 ° - right-turned characters.
Types of underlines by n value are shown below:
n (Hex) Type
0 Canceling an underline.
1 Specifying an underline for 1-dot width.
2 Specifying an underline for 2-dot width.
(10) Specifying 1/6 inch line feed rate (ESC 2)
Code : [1B]h + [32]h
The line feed rate per line is specified by 1/6 inch.
(11) Setting line feed rate of minimum pitch (ESC 3 n)
Code : [1B]h + [33]h + n
*{0n FF} data is described in Hex code.
The line feed rate per line is specified by n/360 inch.
The initial value is n = 60(1/6 inch)(18H), being 4.23 mm line feed rate.