Chapter 6 Configuring Your Printer Using the Menus
-
50
-
Group Menu Menu Item Default Value Range of Values Description
RS-232C Baud 115200 115200
600
1200
2400
4800
9600
14400
19200
38400
57600
Set serial interface baud rate.
New value is valid after power is turned
off and on gain or a reset command is
issued.
RS-232C Parity None None
Odd
Even
Set serial interface communication
parity.
RS-232C Length 8 bits 8 bits
7 bits
Set serial interface character length.
RS-232C Stop bit 1 bit 1 bit
2 bits
Set serial interface stop bits.
RS-232C X-ON Yes No
Yes
Enable or disable serial interface X-ON
flow control.
Network Address 192.168.
254.254
000.000.000.000 -
255.255.255.255
Set network IP address.
Subnet Mask 000.000.
000.000
000.000.000.000 -
255.255.255.255
Set subnet mask.
* Interface
Gateway Address 000.000.
000.000
000.000.000.000 -
255.255.255.255
Set gateway address.
* Save Settings
¾ ¾ ¾
Permanently save configuration values
in non-volatile memory.
Print Pattern Current setting Current setting
Machine Info
Pattern Slanting
Pattern Sample
Choose and execute a test print.
The test pattern or configuration print
can only be produced when there is no
print job is in buffer.
Head Check No Yes
No
Check for faulty printhead elements.
Factory Default No Yes
No
Return to factory default setting values.
* Test Mode
Hex Dump No Yes
No
Enable or disable hex dump mode.