Compaq Deskpro 2000 Personal Computer User Manual


 
Compaq Deskpro 2000 Series of Personal Computers E-11
Table E-18
Continued
Error Code Description Recommended Action
XXXX-41 SCSI bus stayed busy. Replace the indicated device.
XXXX-42 ACK/REQ lines bad. Replace the indicated device.
XXXX-43 ACK did not deassert. Replace the indicated device.
XXXX-44 Parity error. Replace the indicated device.
XXXX-50 Data pins bad. Replace the indicated device.
XXXX-51 Data line 7 bad. Replace the indicated device.
XXXX-52 MSG, C/D, and/or I/O lines bad. Replace the indicated device.
XXXX-53 BSY never went busy. Replace the indicated device.
XXXX-54 BSY stayed busy. Replace the indicated device.
XXXX-60 Controller CONFIG-1 register bad. Replace the indicated device.
XXXX-61 Controller CONFIG-2 register bad. Replace the indicated device.
XXXX-65 Media not unloaded. Replace the indicated device.
XXXX-90 Fan failure.
1. Ensure fan(s) connected.
2. Replace nonfunctional fan(s).
XXXX-91 Over temperature.
1. Ensure proper air flow.
2. Perform required maintenance and cleaning.
XXXX-99 Autoloader reported tapes not
loaded properly.
1. Install tape(s) in autoloader tape drive according to test
instructions.
2. Change autoloader magazine.