Dell 56F Switch User Manual


 
A-10 Installation and Troubleshooting Guide
The possible security level values are:
1 Critical
2 Error
3 Warning
4 Informational
5 Debug
NOTE: If the same error occurs within the same module (for example, the DIAG-
REGERR_UNRST module) but on different ports, the number of occurrences for that
message is incremented in brackets (up to 999), and the error number is not incre-
mented (that is, though it may occur 999 times, it occupies one message in the 320
message buffer).
To display error messages from the front panel:
1. From the front panel, click the Status menu.
2. From the Status window, click Error Log.
3. Scroll through the error log. If no errors occur, the panel displays (.
&6.
If any port fails during a diagnostic test, it is marked ;03 in the status display.
To retest a port which has been marked ;03, clear the port and set to %K using the
diagClearError port# command. This command clears the port status only and does
not clear the logs or change the ports condition.
Some messages contain the following abbreviations:
sb Should Be
er Bits in error
NOTE: If you run the
portStatsShow
or the
diagShow
command prior to running a
test, errors may appear as a result of the normal synchronization process. These
errors should be addressed if the number of errors found increases when running the
portStatsShow
command again
Table A-7 describes possible failure actions.
0/0
%$ )
ramTest Replace mainboard assembly
portRegTest Replace mainboard assembly
centralMemoryTest Replace mainboard assembly
cmlTest Replace mainboard assembly