404 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Configuring a trunk group
12
Additional trunking options
The following trunking options can be performed on ports in deployed trunks. These options are
supported on static trunk ports. Except where noted, these options are also supported on dynamic
(LACP) trunk ports on PowerConnect B-Series FCX Series devices.
The additional trunking options are as follows:
Naming a trunk port
Disabling or re-enabling a trunk port
Deleting a static trunk group (applies to static trunks only)
Specifying the minimum number of ports in a trunk group (applies to static trunks only)
Monitoring a trunk port
Configuring outbound rate shaping on a trunk port
Enabling sFlow forwarding on an individual port in a trunk
STK1(config)#trunk ethe 1/1/1 ethe 2/1/4 ethe 3/1/7 ethe 4/1/2 ethe 5/1/5 ethe
6/1/7 ethe 7/1/2 ethe 7/1/5
Trunk will be created in next trunk deploy.
STK1(config)#trunk deploy
STK1(config)#show trunk
Configured trunks:
Trunk ID: 1
Hw Trunk ID: 1
Ports_Configured: 8
Primary Port Monitored: Jointly
Ports 1/1/1 2/1/4 3/1/7 4/1/2 5/1/5 6/1/7 7/1/2 7/1/5
Port Names none none none none none none none none
Port_Status enable enable enable enable enable enable enable enable
Monitor off off off off off off off off
Rx Mirr Port N/A N/A N/A N/A N/A N/A N/A N/A
Tx Mirr Port N/A N/A N/A N/A N/A N/A N/A N/A
Monitor Dir N/A N/A N/A N/A N/A N/A N/A N/A
Operational trunks:
Trunk ID: 1
Hw Trunk ID: 1
Duplex: None
Speed: None
Tag: Yes
Priority: level0
Active Ports: 0
Ports 1/1/1 2/1/4 3/1/7 4/1/2 5/1/5 6/1/7 7/1/2 7/1/5
Link_Status active active active active active active active active
port_state Forward Forward Forward Forward Forward Forward Forward Forward