PowerConnect B-Series FCX Configuration Guide 117
53-1002266-01
Building an IronStack
5
P-ENGINE 1: type DB90, rev 01
==========================================================================
UNIT 4: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)
==========================================================================
UNIT 4: SL 3: FCX-2XG 2-port 16G Module (2-XFP)
==========================================================================
UNIT 8: SL 1: FCX-48G 48-port Management Module
P-ENGINE 0: type DB90, rev 01
P-ENGINE 1: type DB90, rev 01
==========================================================================
UNIT 8: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)
==========================================================================
800 MHz Power PC processor (version 33/0022) 144 MHz bus
65536 KB flash memory
256 MB DRAM
Monitor Option is on
STACKID 8 system uptime is 21 hours 2 minutes 23 seconds
STACKID 2 system uptime is 21 hours 2 minutes 22 seconds
STACKID 3 system uptime is 21 hours 2 minutes 23 seconds
STACKID 4 system uptime is 21 hours 2 minutes 22 seconds
The system : started=warm start reloaded=by "reload"
My stack unit ID = 8, bootup role = active
*** NOT FOR PRODUCTION ***
NOTE
For field descriptions for the show running config command, refer to “Displaying running
configuration information” on page 143.
NOTE
For field descriptions for the show stack and show stack detail commands, refer to “Displaying
stack information” on page 135.
The output from the show stack command contains a visual diagram of the stack. The dashed
line between ports 1/2/1 and 3/2/1 indicates that this stack is configured in a ring topology. If
the link between ports 1/2/1 and 3/2/1 is lost, the stack topology changes to linear, and the
diagram changes to resemble the following.
active standby
+---+ +---+ +---+
-2/1| 1 |3/1--2/1| 2 |3/1--2/2| 3 |2/1-
+---+ +---+ +---+
The interfaces at either of a stack member are stacking ports. If no interface is displayed, it
indicates that there is no stacking port configured. For example, the following diagram shows
that stack units 1 and 3 each have only one stacking port configured.
active standby
+---+ +---+ +---+
| 1 |3/1--2/1| 2 |3/1--2/2| 3 |
+---+ +---+ +---+
For more detailed information, you can enter the show stack detail command.